SCOPE :-
ANNOUNCIATOR system is most widely used Emergency Communication System. It can be used at hospital nurse station. It helps to ensure safe, high quality healthcare for patients. It is able to provide reliable protection for your patients when and where they need it.
FEATURES:-
-
The Unit works on 230V AC.
-
The Unit is housed in slick Acrylic cabinet.
-
Glass Epoxy PRINTED CIRCUIT BOARD [P.C.B.] is used for better environmental performance.
-
It has 10 (Ten) Press Switches for attending Call.
-
LED’s are on switches to identify the callers by means of numbers marked 1 to 10.
-
Patient can call the nurse for help by ringing the bell. Nurse should attend respective patient’s room by pressing respective switch given on the unit. When an associated call is activated, the LED will ON and audible tone is generated by buzzer. After pressing that switch, LED of particular switch and Buzzer is resetted.
But if two CALLs comes at the same time then LED & buzzer will turn OFF after attending first Call (pressing first switch) and LED of second switch will glow untill CALL is attended.
-
Indications:-
-
Video :- RED LED [3MM] on Press Switch for Incoming CALL.
-
Audio :- Buzzer for audible tone.
-
Opening is provided at bottom of the cabinet for clarity of Sound output.
-
Superior quality industrial type 10 amp connector is used.
-
It is surface mount unit with hanging arrangement.
TECHNICAL SPECIFICATIONS:-
-
SR. NOS.
TESTS
REMARK
1
Visual Inspection :-
a) Acrylic cabinet
OK
b) Fitting of component
OK
2
Works on 230V AC
OK
3
Glass Epoxy P. C. B.
OK
4
All components of good quality
OK
5
Ten Press Switches for attending CALL
OK
6
Indication :-
a) Video : RED LED for Incoming CALL
OK
b) Audio : Buzzer for audible tone
OK
All Technical & Mechanical specifications are subject to change, without prior notice, for better performance & up gradation.
End.